Skip to content

Water Hardness in Watertown, South Dakota

Does Watertown have hard water?

Yes, very. This is among the harder municipal supplies in the country.

City of Watertown delivers water at 280 ppm (16.4 grains per gallon), which this site rates Very Hard and the USGS classifies as very hard (over 180 mg/L as calcium carbonate). That is 30 ppm harder than the South Dakota average of 250 ppm, and harder than 86% of the 428 cities listed on this site.

Hardness 280 ppm 16.4 grains per gallon
USGS Class Very hard Softener recommended
Rank in SD 4 of 8 hardest first
Water Source Ground City of Watertown

280 PPM in Every Unit

Appliance manuals, test strips and utility reports each use a different hardness unit. These are the same Watertown reading expressed in each one.

UnitWatertownUsed by
mg/L as CaCO₃ (ppm)280Utility water-quality reports, USGS
Grains per gallon (gpg)16.4Softener sizing, most US dishwasher manuals, test strips
German degrees (°dH)15.7European-made dishwashers and coffee machines
French degrees (°fH)28Some filter and descaler instructions
mmol/L2.8Laboratory reports

Dishwasher setting for Watertown: 16.4 gpg or 15.7 °dH, rounded up to the machine's nearest step. The USGS bands are soft 0–60, moderately hard 61–120, hard 121–180 and very hard above 180 mg/L; this site splits the top band at 250 to separate hard from very hard.

What 280 PPM Does in a Watertown Home

At 280 ppm the supply is among the harder municipal water in the country. Scale restricts fixtures within a year or two, tankless heaters are at real risk of plugging, and bathing leaves skin and hair feeling dry. A softener is close to a necessity rather than an upgrade.

Water heaters

The clearest measured effects of hardness come from a 2009 study the Water Quality Research Foundation commissioned from the Battelle Institute. Scaled to Watertown's 16.4 gpg, its gas storage-heater results work out as follows; softened water held full efficiency in the same tests.

ApplianceBattelle findingAt 16.4 gpg
Gas storage heater, 50 gal hot water/day4% efficiency loss per 5 gpg over 15 years13% loss
Gas storage heater, 100 gal/day8% per 5 gpg, capped at the 48% measured at 30 gpg26% loss
Electric storage heater0.4 lb of scale per year per 5 gpg1.3 lb/year
Tankless gas heaterPlugged with scale after 1.6 years on 26 gpg waterDescale yearly or soften
ShowerheadsLost 75% of flow in under 18 months on hard waterExpect visible scaling within a year

Laundry and dishes

Hardness minerals bind with detergent before it can clean, which is why dose charts step up for hard water. For Watertown: Use the label's heavy-soil or hard-water dose. Softening the water lets you drop back to the minimum dose.

Sizing a Water Softener for Watertown

Softener capacity is the grains of hardness a unit removes between regenerations. At 16.4 gpg, each person using 75 gallons a day adds about 1,230 grains daily. The table assumes one regeneration a week and an efficient salt setting of 1 lb per 3,000 grains.

HouseholdGrains/dayGrains/7 daysSuggested capacitySalt/month
2 people 2,460 17,220 24,000 grain ~34 lb
3 people 3,690 25,830 32,000 grain ~46 lb
4 people 4,920 34,440 40,000 grain ~57 lb
5 people 6,150 43,050 48,000 grain ~69 lb

Add iron at 1 gpg per 1 ppm of dissolved iron if your test shows any, and size up rather than down: a unit that regenerates less often uses less salt per grain removed.

Where Watertown's Water Comes From

City of Watertown supplies Watertown from groundwater drawn from wells. Groundwater picks up calcium and magnesium as it moves through limestone, dolomite and chalk, which is why well-fed systems are usually harder than river-fed ones.

The supply has a pH of 7.9, inside the EPA secondary range of 6.5–8.5, and total dissolved solids of 450 mg/L, below the EPA secondary standard of 500 mg/L but high enough to taste minerally. Hardness is the largest part of dissolved solids in most municipal water, which is why the two tend to rise together.

The figure on this page is the utility's reported average. Blended systems vary by season and neighborhood, so for the current number check the utility's Consumer Confidence Report, which the EPA indexes at Find Your Local CCR, or test the tap with a strip kit.

Treatment Options for 280 PPM

Ranked for Watertown's hardness level. Only the first group actually removes calcium and magnesium; conditioners and descalers change how scale behaves without lowering the reading.

Other Cities in South Dakota

Watertown ranks 4 of 8 listed South Dakota cities, hardest first. Hardness tracks geology and source more than distance, so neighboring cities can differ widely.

CityHardness (PPM)GPGLevelSource
Watertown 280 ppm 16.4 Very Hard Ground
Mitchell 310 ppm 18.1 Very Hard Ground
Aberdeen 300 ppm 17.5 Very Hard Ground
Huron 290 ppm 17 Very Hard Ground
Brookings 260 ppm 15.2 Very Hard Ground
Pierre 230 ppm 13.5 Hard Mixed
Sioux Falls 220 ppm 12.9 Hard Ground
Rapid City 200 ppm 11.7 Hard Mixed

Frequently Asked Questions

Does Watertown have hard water?

Yes, very. This is among the harder municipal supplies in the country. Watertown's water measures 280 ppm (16.4 grains per gallon), which the USGS classifies as very hard (over 180 mg/L as calcium carbonate). That is 30 ppm harder than the South Dakota average of 250 ppm and harder than 86% of the 428 cities listed on this site.

What is the water hardness in Watertown in grains per gallon?

16.4 grains per gallon. The same 280 mg/L reading is 15.7 German degrees (°dH), 28 French degrees (°fH) and 2.8 mmol/L; 1 grain per gallon equals 17.1 mg/L as calcium carbonate.

Do I need a water softener in Watertown?

For most households, yes. At 280 ppm the Battelle Institute's water-heater study implies a gas storage heater loses roughly 13% of its efficiency over 15 years at 50 gallons of hot water a day and 26% at 100 gallons, and fixtures scale within months. A salt-based softener removes the hardness; a salt-free conditioner only limits where the scale sticks.

What size water softener does a family of four need in Watertown?

About 40,000 grains. Four people at 75 gallons each per day remove 4,920 grains of hardness daily, or 34,440 grains between weekly regenerations, so the smallest standard unit that covers a week is 40,000 grains. Expect roughly 57.2 lb of salt a month at an efficient setting.

What hardness setting should my dishwasher use in Watertown?

Set it for 16.4 grains per gallon, or 15.7 °dH if the manual uses German degrees; most machines take the nearest step up. The setting controls how much rinse aid and, on models with a built-in softener, how much salt the machine uses.

Where does Watertown's water come from?

City of Watertown supplies Watertown from groundwater drawn from wells. Groundwater picks up calcium and magnesium as it moves through limestone, dolomite and chalk, which is why well-fed systems are usually harder than river-fed ones. The utility's annual Consumer Confidence Report lists the current hardness, pH and dissolved solids; the EPA keeps a finder for these reports.

How does Watertown compare with other cities in South Dakota?

Watertown ranks 4 of 8 South Dakota cities listed here, hardest first, and is 30 ppm harder than the South Dakota average of 250 ppm. Nationally it is harder than 86% of the 428 cities listed on this site; the median listed city is 125 ppm.

How This Page Works

  • The hardness, pH, dissolved-solids, source and utility values are the figures reported by City of Watertown; every other number on the page is arithmetic on them. The site's five-band scale (soft, slightly hard, moderately hard, hard, very hard) is shown alongside the four-band USGS classification.
  • Unit conversions use 17.1 mg/L per grain per gallon, 17.85 mg/L per °dH, 10 mg/L per °fH and 100.09 mg/L per mmol/L of calcium carbonate.
  • Softener sizing assumes 75 gallons per person per day, regeneration every 7 days, standard capacities from 24,000 to 80,000 grains and 1 lb of salt per 3,000 grains. A dealer will size from your meter and a tap test.
  • Water-heater figures scale the Battelle Institute's 2009 per-5-gpg results linearly to this city's hardness and cap at the 48% loss Battelle measured at 30 gpg; the study ran 90-day accelerated tests, not 15 real years.
  • Sources: USGS Water Science School, Hardness of Water (classification bands); Water Quality Research Foundation, Battelle study release, April 13 2010 and WQA's Softened Water Benefits Studies page; US EPA, Secondary Drinking Water Standards (TDS 500 mg/L, pH 6.5–8.5) and Consumer Confidence Reports.

Test & Treat Your Water

Find out exactly what's in your water and get the right solution.

Some links above are affiliate links — if you buy through them we may earn a small commission at no extra cost to you. As an Amazon Associate we earn from qualifying purchases.